The figure (eps) shows the barrel and extended barrel sections of the Tile Calorimeter. Signals from the scintillators are grouped into the rectangular cells shown and each cell is viewed by a pair of photomultipliers (called L and R in the tables below). In the barrel section, cells Bi and Ci are viewed by the same pair of photomultipliers. The cell dimensions are chosen to obtain pseudo-projective towers of nominal width delta-eta = 0.1. The D cells, which normally contain very little energy, have a width delta-eta = 0.2. One PMT is put in each of the two appropriate delta-eta = 0.1 towers. Thus each tower contains three longitudinal segments. The PMT in bold font is also connected to the Muon Output trigger.
BARREL | |||
---|---|---|---|
Eta | PMTs by cell | PMT Positions | Adder Position |
0.0-0.1 | A1R A1L BC1R BC1L D0R | 5 2 3 4 1 | 4 |
0.1-0.2 | A2R A2L BC2R BC2L D1L | 9 6 7 8 14 | 7 |
0.2-0.3 | A3R A3L BC3R BC3L D1R | 11 10 13 12 15 | 10 |
0.3-0.4 | A4R A4L BC4R BC4L D2L | 19 16 17 18 26 | 15 |
0.4-0.5 | A5R A5L BC5R BC5L D2R | 21 20 23 22 27 | 21 |
0.5-0.6 | A6R A6L BC6R BC6L D3L | 25 24 29 30 40 | 28 |
0.6-0.7 | A7R A7L BC7R BC7L D3R | 31 28 35 36 43 | 31 |
0.7-0.8 | A8R A8L BC8R BC8L | 37 34 41 42 | 34 |
0.8-1.0 | A9R A9L B9R B9L A10R A10L | 39 38 45 46 47 48 | 42 |
EXTENDED BARREL | |||
---|---|---|---|
Eta | PMTs by cell | PMT Positions | Adder Position |
0.8-1.0 | C10R C10L D4R D4L D5R | 5 6 3 4 17 | 7 |
1.0-1.1 | B11R B11L D5L | 9 10 18 | 10 |
1.1-1.2 | A12R A12L B12R B12L D6R | 7 8 15 16 37 | 21 |
1.2-1.3 | A13R A13L B13R B13L D6L | 11 12 23 24 38 | 15 |
1.3-1.4 | A14R A14L B14R B14L | 21 22 33 34 | 28 |
1.4-1.6 | A15R A15L B15R B15L A16R A16L | 29 30 43 44 41 42 | 34 |
Gap/Crack | E1 E2 E3 E4 | 13 14 1 2 |