Status ID Category Rule Description Severity Information Area Extra Information
Pass IO_000001 Capacity Checks Number of pins in an I/O bank should not exceed the number of locations available. Critical 0 such failures found. I/O  
Pass IO_000002 Capacity Checks Number of clocks in an I/O bank should not exceed the number of clocks available. Critical 0 such failures found. I/O  
Pass IO_000003 Capacity Checks Number of pins in a Vrefgroup should not exceed the number of locations available. Critical 0 such failures found. I/O  
Inapplicable IO_000004 Voltage Compatibility Checks The I/O bank should support the requested VCCIO. Critical No IOBANK_VCCIO assignments found. I/O  
Pass IO_000005 Voltage Compatibility Checks The I/O bank should not have competing VREF values. Critical 0 such failures found. I/O  
Pass IO_000006 Voltage Compatibility Checks The I/O bank should not have competing VCCIO values. Critical 0 such failures found. I/O  
Pass IO_000007 Valid Location Checks Checks for unavailable locations. Critical 0 such failures found. I/O  
Inapplicable IO_000008 Valid Location Checks Checks for reserved locations. Critical No reserved LogicLock region found. I/O  
Pass IO_000009 I/O Properties Checks for One I/O The location should support the requested I/O standard. Critical 0 such failures found. I/O  
Pass IO_000010 I/O Properties Checks for One I/O The location should support the requested I/O direction. Critical 0 such failures found. I/O  
Pass IO_000011 I/O Properties Checks for One I/O The location should support the requested Current Strength. Critical 0 such failures found. I/O  
Pass IO_000012 I/O Properties Checks for One I/O The location should support the requested On Chip Termination value. Critical 0 such failures found. I/O  
Inapplicable IO_000013 I/O Properties Checks for One I/O The location should support the requested Bus Hold value. Critical No Enable Bus-Hold Circuitry assignments found. I/O  
Inapplicable IO_000014 I/O Properties Checks for One I/O The location should support the requested Weak Pull Up value. Critical No Weak Pull-Up Resistor assignments found. I/O  
Inapplicable IO_000015 I/O Properties Checks for One I/O The location should support the requested PCI Clamp Diode. Critical No Clamping Diode assignments found. I/O  
Pass IO_000018 I/O Properties Checks for One I/O The I/O standard should support the requested Current Strength. Critical 0 such failures found. I/O  
Pass IO_000019 I/O Properties Checks for One I/O The I/O standard should support the requested On Chip Termination value. Critical 0 such failures found. I/O  
Inapplicable IO_000020 I/O Properties Checks for One I/O The I/O standard should support the requested PCI Clamp Diode. Critical No Clamping Diode assignments found. I/O  
Inapplicable IO_000021 I/O Properties Checks for One I/O The I/O standard should support the requested Weak Pull Up value. Critical No Weak Pull-Up Resistor assignments found. I/O  
Inapplicable IO_000022 I/O Properties Checks for One I/O The I/O standard should support the requested Bus Hold value. Critical No Enable Bus-Hold Circuitry assignments found. I/O  
Pass IO_000023 I/O Properties Checks for One I/O The I/O standard should support the Open Drain value. Critical 0 such failures found. I/O  
Pass IO_000024 I/O Properties Checks for One I/O The I/O direction should support the On Chip Termination value. Critical 0 such failures found. I/O  
Pass IO_000026 I/O Properties Checks for One I/O On Chip Termination and Current Strength should not be used at the same time. Critical 0 such failures found. I/O  
Inapplicable IO_000027 I/O Properties Checks for One I/O Weak Pull Up and Bus Hold should not be used at the same time. Critical No Enable Bus-Hold Circuitry or Weak Pull-Up Resistor assignments found. I/O  
Inapplicable IO_000045 I/O Properties Checks for One I/O The I/O standard should support the requested Slew Rate value. Critical No Slew Rate assignments found. I/O  
Inapplicable IO_000046 I/O Properties Checks for One I/O The location should support the requested Slew Rate value. Critical No Slew Rate assignments found. I/O  
Inapplicable IO_000047 I/O Properties Checks for One I/O On Chip Termination and Slew Rate should not be used at the same time. Critical No Slew Rate assignments found. I/O  
Pass IO_000034 SI Related Distance Checks Single-ended outputs should be 0 LAB row(s) away from a differential I/O. High 0 such failures found. I/O  
---- ---- Disclaimer LVDS rules are checked but not reported. None ---- Differential Signaling  
---- ---- Disclaimer Memory interface related rules are checked but not reported. None ---- Memory Interfaces  
---- ---- Disclaimer OCT rules are checked but not reported. None ---- On Chip Termination