Date: Thu, 27 Jan 2000 15:56:17 +0100 To: RLC@uccdfj.uchicago.edu CC: SIMONE.DONATI@PI.INFN.IT, ZANETTI@trieste.infn.it From: Anna Maria Subject: RE: Merger Front Panel Dear Ray, there are some errors in your drawing of the Merger: 1) the connector holes must have the same dimensions. This is not the case in your drawing because there are 6 wrong vertical positions of the connector holes. I list them here: TS drawing CHI drawing (mm) (inch) (inch) 21.8 0.858 0.873 233.6 9.197 9.182 238.6 9.394 9.409 287.8 11.331 11.316 292.8 11.528 11.543 342.0 13.465 13.450 2) Two holes for pcb mounting brackets: wrong dia. and hor.pos. TS drawing CHI drawing (mm) (inch) (inch) diameter 2.5 0.098 0.090 hor. pos. 7.6 0.299 0.307 I spoke with Simone Donati: the modifications 1) and 2) must be applied to the XTF-B as well. About the lettering: 3) the letters CE for the test point (over the CDF led) is missing. 4) There are two "OUTPUT 2". The top one is "OUTPUT 1" instead. 5) INFN TRIESTE should be "I N F N T R I E S T E" that is with one blank characters between characters and some extra space between words. I think it would be nice to have a prototype before going to production. cheers Anna Maria